Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • Article
  • Published:

Validation of a cuff-based device for measuring carotid-femoral pulse wave velocity in children and adolescents

Abstract

Carotid-femoral pulse wave velocity is associated with arterial stiffness in major elastic arteries, and predicts future cardiovascular events. However, little is known about carotid-femoral pulse wave velocity as a marker of vascular health in children. Semi-automated cuff-based devices for assessing pulse wave velocity are increasingly popular, although these utilize an algorithm developed and validated in adults. Physiological differences between adults and children may, however, reduce the accuracy of cuff-based methods. We sought to determine the accuracy of a cuff-based pulse wave velocity device in healthy children, and determine whether a novel age-appropriate algorithm increases accuracy. We recruited 29 healthy children between the ages of 2 and 20 years. Pulse wave velocity was measured both by using a tonometer on the carotid artery and an inflated cuff on the thigh, and using a tonometer on both the carotid artery and femoral artery as a reference standard. Accuracy of the cuff-based device with its standard algorithm developed in adults, and a novel age-appropriate algorithm corrected for physiological differences in leg pulse wave velocity was assessed with Regression analysis and Bland-Altman plots. Cuff-based device estimates of pulse wave velocity had excellent agreement to the reference standard (Δ = −0.26 ms−1 [SD 0.44]). The novel age-appropriate algorithm improved the accuracy of the cuff-based method (Δ = 0.02 ms−1 [SD 0.44]). The cuff-based semi-automatic approach estimates carotid-femoral pulse wave velocity with excellent agreement to the reference standard. However, adjusting the algorithm for known differences in leg pulse wave velocity further improves the accuracy of cuff-based measurement in children and adolescents.

This is a preview of subscription content, access via your institution

Access options

Buy this article

Prices may be subject to local taxes which are calculated during checkout

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Ben-Shlomo Y, Spears M, Boustred C, May M, Anderson SG, Benjamin EJ, et al. Aortic pulse wave velocity improves cardiovascular event prediction an individual participant meta-analysis of prospective observational data from 17,635 subjects. J Am Coll Cardiol. 2014;63:636–46.

    Article  Google Scholar 

  2. Vlachopoulos C, Aznaouridis K, Stefanadis C. Prediction of cardiovascular events and all-cause mortality with arterial stiffness. a systematic review and meta-analysis. J Am Coll Cardiol. 2010;55:1318–27.

    Article  Google Scholar 

  3. Laurent S, Cockcroft J, Van Bortel L, Boutouyrie P, Giannattasio C, Hayoz D, et al. Expert consensus document on arterial stiffness: methodological issues and clinical applications. Eur Heart J. 2006;27:2588–605.

    Article  Google Scholar 

  4. Wilkinson IB, McEniery CM, Schillaci G, Boutouyrie P, Segers P, Donald A, et al. ARTERY Society guidelines for validation of non-invasive haemodynamic measurement devices: Part 1, arterial pulse wave velocity. Artery. Research. 2010;4:34–40.

    Google Scholar 

  5. Townsend RR, Wilkinson IB, Schiffrin EL, Avolio AP, Chirinos JA, Cockcroft JR, et al. Recommendations for improving and standardizing vascular research on arterial stiffness: A scientific statement from the american heart association. Hypertension. 2015;66:698–722.

    Article  CAS  Google Scholar 

  6. Butlin M, Qasem A, Battista F, Bozec E, McEniery CM, Millet-Amaury E, et al. Carotid-femoral pulse wave velocity assessment using novel cuff-based techniques: comparison with tonometric measurement. J Hypertens. 2013;31:2237–43.

    Article  CAS  Google Scholar 

  7. Avolio AP, Chen SG, Wang RP, Zhang CL, Li MF, O’Rourke MF. Effects of aging on changing arterial compliance and left ventricular load in a northern Chinese urban community. Circulation. 1983;68:50–8.

    Article  CAS  Google Scholar 

  8. Stabouli S, Printza N, Zervas C, Dotis J, Chrysaidou K, Maliahova O, et al. Comparison of the SphygmoCor XCEL device with applanation tonometry for pulse wave velocity and central blood pressure assessment in youth. J Hypertens. 2019;37:30–6.

    Article  CAS  Google Scholar 

  9. Urbina EM, Williams RV, Alpert BS, Collins RT, Daniels SR, Hayman L, et al. Noninvasive assessment of subclinical atherosclerosis in children and adolescents: Recommendations for standard assessment for clinical research: A scientific statement from the American Heart Association. Hypertension. 2009;54:919–50.

    Article  CAS  Google Scholar 

  10. Lantelme P, Mestre C, Lievre M, Gressard A, Milon H. Heart rate: An important confounder of pulse wave velocity assessment. Hypertens: J Am Heart Assoc. 2002;39:1083–7.

    Article  CAS  Google Scholar 

  11. Haesler E, Lyon X, Pruvot E, Kappenberger L, Hayoz D. Confounding effects of heart rate on pulse wave velocity in paced patients with a low degree of atherosclerosis. J Hypertens. 2004;22:1317–22.

    Article  CAS  Google Scholar 

  12. Butlin M, Qasem A. Large artery stiffness assessment using sphygmocor technology. Pulse. 2017;4:180–92.

    Article  Google Scholar 

  13. Cruickshank JK, Silva MJ, Molaodi OR, Enayat ZE, Cassidy A, Karamanos A, et al. Ethnic differences in and childhood influences on early adult pulse wave velocity: The determinants of adolescent, now young adult, social wellbeing, and health longitudinal study. Hypertension. 2016;67:1133–41.

    Article  CAS  Google Scholar 

  14. Sugawara J, Hayashi K, Yokoi T, Tanaka H. Carotid–femoral pulse wave velocity: Impact of different arterial path length measurements. Artery. Research. 2009;4:27–31.

    Google Scholar 

  15. Huybrechts SAM, Devos DG, Vermeersch SJ, Mahieu D, Achten E, de Backer TLM, et al. Carotid to femoral pulse wave velocity: a comparison of real travelled aortic path lengths determined by MRI and superficial measurements. J Hypertens. 2011;29:1577–82.

    Article  CAS  Google Scholar 

  16. Weir-McCall JR, Brown L, Summersgill J, Talarczyk P, Bonnici-Mallia M, Chin SC, et al. Development and validation of a path length calculation for carotid-femoral pulse wave velocity measurement: A TASCFORCE, SUMMIT, and caerphilly collaborative venture. Hypertens (Dallas, Tex: 1979). 2018;71:937.

    Article  CAS  Google Scholar 

  17. Williams B, Mancia G, Spiering W, Agabiti Rosei E, Azizi M, Burnier M, et al. 2018 ESC/ESH Guidelines for the management of arterial hypertension. Eur Heart J. 2018;39:3021–104.

    Article  Google Scholar 

  18. Foo J, Wilson S, Wang P. Factors that affect pulse wave time transmission in the monitoring of cardiovascular system. J Clin Monit Comput. 2008;22:141–7.

    Article  Google Scholar 

Download references

Acknowledgements

This work was supported by a NSW CVRN Research Development Project Grant (#101135) from the National Heart Foundation of Australia;. MRS is supported by a Future Leader fellowship from the National Heart Foundation of Australia (#100419). Equipment was provided by AtCor Medical for use during this project.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Michael R. Skilton.

Ethics declarations

Conflict of interest

Dr Ahmed Qasem is an employee of AtCor Medical. The other authors declare that they have no conflict of interest.

Additional information

Publisher’s note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Cai, T.Y., Meroni, A., Dissanayake, H. et al. Validation of a cuff-based device for measuring carotid-femoral pulse wave velocity in children and adolescents. J Hum Hypertens 34, 311–318 (2020). https://doi.org/10.1038/s41371-019-0191-1

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1038/s41371-019-0191-1

Search

Quick links