Since the pioneering work by Ernst Abbe 150 years ago, many engineering innovations have improved the performance of microscope objectives1. Nonetheless, application domains exist for which better and more cost-efficient objectives still are highly desirable. One of these domains is imaging samples processed with tissue clearing techniques2,3, which render entire organs or organisms transparent while retaining fluorescent labeling. Given that, over the course of the past decade, clearing of entire mouse brains (≈1 cm3) has become routine2,4,5 and that clearing of entire mice and human organs is feasible6,7,8, there is a need for microscope objectives that are suitable for imaging large, cleared samples at high resolution. This demand poses a challenging optical engineering problem because imaging at high resolution requires increasing the numerical aperture (NA), which complicates the correction of aberrations and necessitates more lens elements. Beyond that, the large size of cleared samples requires objectives with long working distances (WDs), while, at the same time, large fields of view (FOVs) are necessary to allow imaging with high throughput. The most challenging engineering problem by far is, however, that published clearing protocols require immersion media with a diversity of the refractive index n, ranging from water (n = 1.33) for expansion microscopy9 to typical organic solvents such as dibenzyl ether10 (DBE) or ethyl cinnamate11 (ECI) with n = 1.56. Some commercial objectives have a correction collar that moves an internal lens group to minimize index-dependent aberrations, but, for high-NA objectives, designers often opt for narrowing the index range to keep the costs under control. For example, the Olympus XLSLPLN25XGMP combines NA = 1.0 with 8-mm WD but is restricted to n = 1.41–1.52. Covering a larger index range is possible at the expense of resolution (for example, the Olympus XLPLN10XSVMP has an NA of 0.6, 8-mm WD and n = 1.33–1.52). Such objectives typically have 13–15 lenses and are very expensive. Despite this considerable effort, indices around 1.56 are outside the specified range. And, not least, media such as DBE, ECI or benzyl alcohol/benzyl benzoate (BABB) can dissolve lens cements so that chemically resistant dipping cap designs are required. Few such options are available, of which one is an ASI/Special Optics objective (54-12-8) that covers the entire range from 1.33 to 1.56 with good chemical compatibility, featuring 10-mm WD at an NA of 0.7. However, scaling this design up to higher NA, longer WD and FOV beyond 1 mm has not been achieved so far.

To address this challenge, we introduce an approach for designing a multi-immersion objective based on a mirror instead of lenses. The underlying idea is that the reflection of a light ray by a mirror is independent of the refractive index of the medium the mirror is in contact with. Consequently, if we submerge a curved mirror inside a liquid-filled chamber and use it to focus light, the ray paths and location of the focus do not change when changing the bulk index of the immersion medium. An invariant ray path means that any monochromatic aberrations, such as spherical aberration or coma, stay constant even though the NA of the objective scales with the refractive index of the medium. This is markedly different compared to lens-based multi-immersion designs where any medium change causes additional aberrations that need to be accounted for. In addition, reflective objective designs often have a longer WD than refractive designs at similar NA. This combination of features means that reflective optical systems are excellent templates for long-WD multi-immersion objectives. Although, to our knowledge, such a design has not been previously applied in bioimaging, it is found in nature, where each of the hundreds of eyes of scallops contains a curved mirror to form an image12 (Fig. 1a). Each mirror is in direct contact with the liquid-filled space containing the photoreceptors. Each eye also contains a lens, which is not, however, the primary image-forming element13. This combination of a lens and a mirror is reminiscent of the optical design of the Schmidt telescope14, a mirror-based wide-field telescope design commonly used in astronomy since the 1930s (Fig. 1b). A Schmidt telescope is based on a spherical mirror that, as a standalone element, would create a heavily aberrated image due to spherical aberration. By adding a refractive aspherical correction plate in the center of curvature of the mirror, Bernhard Schmidt (1879–1935) created a telescope design that corrects the spherical aberration and provides excellent image quality over a large FOV. Owing to this wide-field capability, such telescopes are exceptionally well suited for surveys of the night sky. For example, the Kepler space telescope is a Schmidt telescope optimized for exoplanet detection15,16. Most Schmidt telescopes share the characteristic that, due to the rotational symmetry of the spherical mirror, the image surface of a Schmidt telescope is curved as well. The usage of an aspherical correction plate in combination with curved mirrors forms a general solution that can be applied to a wide variety of optical design problems. Indeed, shortly after the Schmidt telescope became widely known, it was recognized that this principle could be useful to build microscope objectives17,18. However, apart from non-imaging flow cytometry19, there is no application of the Schmidt principle in modern biophotonics.

Fig. 1: Concept of the multi-immersion Schmidt objective.
figure 1

a, Our approach is inspired by the anatomy of the scallop eye. In this eye design, a curved mirror in contact with a liquid forms an image on a transparent layer of photoreceptors. b, A second inspiration is the Schmidt telescope, a mirror-based wide-field telescope design that consists of a spherical mirror and an aspherical correction plate. c, We synthesize both concepts into a multi-immersion objective design that provides a sharp image in any homogeneous medium (center). Reflection off the mirror does not depend on the refractive index n of the immersion medium (right). To avoid additional refraction at the inner surface of the correction plate, we deform this surface such that all passing rays are close to normal incidence (left).

Results

Turning a Schmidt telescope into an immersion objective

We reasoned that it is possible to turn a Schmidt telescope into an immersion microscope objective by a series of conceptual steps (Fig. 1c and Supplementary Video 1):

  1. 1.

    Downscaling the design from the meter-sized apertures common in astronomy to a centimeter-sized aperture suitable for a microscope;

  2. 2.

    Replacing the detector in the focus of the telescope with a fluorescently labeled sample;

  3. 3.

    Focusing and scanning an excitation beam instead of focusing light from stars—for example, a near-infrared ultra-fast pulsed laser beam for two-photon microscopy;

  4. 4.

    Filling the entire inner space between the mirror and the correction plate with an immersion liquid.

We noted that this approach results in objective designs with excellent simulated image quality; however, the optimal shape of the aspherical surface correcting for spherical aberration needs to be tailored specifically to each immersion medium. Such designs with simple Schmidt correction plates are, thus, immersion objectives but not multi-immersion capable. The reason is that refraction at the interface between correction plate and immersion medium introduces additional index-dependent spherical aberration. To circumvent this problem, we make use of an edge case of the law of refraction: no matter how big the index difference at a refractive interface is, a ray at normal incidence is not refracted—that is, it does not change its propagation direction. Therefore, we additionally shape the inner surface of the correction plate such that, at all locations, the passing rays are at normal incidence. In other words, the first aspherical surface of the correction plate deforms the incoming parallel wavefront to counteract the spherical aberration of the spherical mirror, and the second surface is then shaped exactly like this deformed wavefront. As the wavefront passes the interface unchanged, no additional (index-dependent) aberrations are introduced. We refer to this interface as a ‘minimally refractive’ surface because it does not have any net refractive power. Because in typical laser scanning microscopes the scan angles at the objective are usually only a few degrees, even off-axis ray bundles strike the minimally refractive surface at near-normal incidence, which allows the design to have millimeter-sized FOVs. We term the resulting multi-immersion Schmidt-telescope-turned microscope objective a ‘Schmidt objective’.

Design of a multi-photon Schmidt objective

Although our concept can be used to design objectives for a wide variety of imaging modalities, we opted to demonstrate the design as a multi-photon objective. The reason is that many multi-photon techniques, such as two-photon microscopy, require only a single laser source, and the excitation spectrum is so narrow that no color correction is necessary, and, due to non-descanned detection, the collection path does not have to be color-corrected. Consequently, the design can be kept extremely simple: our multi-photon objective design has only two optical elements and can be used with a tunable ultrafast excitation laser in the 750–1,000-nm range. Owing to the reflective geometry, the sample sits in between the mirror and the correction plate. Therefore, we define the working distance as the axial spacing between the focus and the outer rim of the mirror because this is the feasible z-range before a sample holder would collide with the mirror (Extended Data Fig. 1a). For our Schmidt objective, this working distance is 11 mm. As the on-axis ray path is independent of the refractive index of the immersion medium, the NA scales linearly with n, and no correction collar is required. In air and using 800-nm excitation light, the design has an NA of 0.69 and a diffraction-limited field of view (dFOV) of 1.6 mm diameter (Extended Data Fig. 1b). The system has an index-independent entrance pupil diameter of 22 mm. As a result, the etendue (or optical invariant of the system) is constant, and the product of NA and FOV is invariant as well. Consequently, in a higher-index medium such as water, the NA increases to 0.92, but the dFOV decreases to 1.4 mm. For typical organic solvents, such as ECI, DBE or BABB with an index of 1.56, the NA reaches 1.08, and the dFOV is 1.1 mm. The focal surface of the Schmidt objective is curved with a radius of 15.68 mm. Supplementary Note 1 provides an overview of the theory underlying our design approach. To turn this design into a prototype, we designed an immersion chamber around the optical components of the objective and integrated it into a custom horizontal multi-photon microscope (Fig. 2a–c). We chose a horizontal setup as it makes the exchange of immersion media and samples straightforward. In our prototype, the mirror is attached to a motorized xyz stage and needs to be aligned relative to the correction plate. We opted for this approach because, initially, it was unclear how often the mirror would require cleaning and possibly replacement due to damaged coatings. In practice, however, we did not observe any coating damage even after prolonged immersion of the mirror in imaging media, such as DBE, BABB or ECI (Supplementary Note 1). This means that future Schmidt objectives can be designed with a mirror that is fixed in the immersion chamber.

Fig. 2: Setup and characterization.
figure 2

a, Overview of the multi-photon microscopy setup. In our prototype, the position of the spherical mirror needs to be aligned relative to the correction plate for optimum image quality. This design allows for straightforward cleaning of the mirror when switching immersion media. To create a z-stack, the sample is moved along the optical axis. DC indicates a dichroic mirror that separates the emitted fluorescence from the excitation beam. b, The prototype objective consists of an immersion chamber and a mirror. c, Assembled microscope objective. d, xyz views of PSF measurements of 200-nm fluorescent beads imaged at refractive indices ranging from n = 1.00 (air), n = 1.33 (water) and n = 1.45 (FS, Cargille fused silica matching oil) to n = 1.51 (Cargille oil type A). Because NA is proportional to n, an increase in n leads to higher NA and, thus, a smaller PSF. e, PSF uniformity over the FOV. PSF measurements were carried out on-axis and at a scan angle of 1.75°, which was simulated to be the maximum theoretical diffraction-limited scan angle for the total system (Extended Data Fig. 1). As the magnification of the objective is proportional to n, the FOV diameter decreases with increasing index. Diffraction-limited theoretical values are indicated by the red dashed lines. The PSF FWHM (±s.e.m.) was measured for eight beads for each FOV location and immersion medium. a.u., arbitrary units.

Characterization of the multi-photon Schmidt objective

We characterized the optical resolution of the objective by imaging 200-nm fluorescent beads at 800-nm excitation wavelength (Fig. 2d,e). In air (NA = 0.69), we measured an on-axis point spread function (PSF) with a full width at half maximum (FWHM) of 0.56 ± 0.01 µm in x (mean ± s.e.m.), 0.49 ± 0.07 µm in y and 1.93 ± 0.01 µm in z (n = 8 beads). In water, the PSF size decreased to 0.42 ± 0.04 µm in x, 0.43 ± 0.03 µm in y and 1.65 ± 0.1 µm in z (n = 8 beads). When filling the objective with an immersion oil with n = 1.45, the PSF size further decreased to 0.36 ± 0.01 µm in x, 0.33 ± 0.01 µm in y and 1.33 ± 0.09 µm in z (n = 8 beads). Further increasing the index to n = 1.51 led to PSF size of 0.36 ± 0.02 µm in x, 0.32 ± 0.02 µm in y and 1.36 ± 0.01 µm in z (n = 8 beads). Across the index range, the on-axis PSF sizes were similar to diffraction-limited values20. Imaging parameters are listed in Supplementary Table 1. According to our simulations (Extended Data Fig. 1b–d), our objective supports a diffraction-limited FOV of 1.7 mm in air, 1.4 mm in water and 1.1 mm at n = 1.56. Due to additional off-axis aberrations introduced by our scan and tube lens, the whole system is diffraction limited only up to a maximum scan angle of ±1.75°, which corresponds to a dFOV of 0.74 mm in air, 0.68 mm in water and 0.54 mm at n = 1.56 (Extended Data Fig. 1e–g). Therefore, we characterized the PSFs at a scan angle of ±1.75° (Fig. 2e and Extended Data Fig. 2) and found that the off-axis PSFs are in good agreement with our simulations.

Imaging examples using the Schmidt objective

To demonstrate the imaging capabilities of our Schmidt objective, we imaged both cleared and living samples (Fig. 3). In cleared samples, we first acquired low-resolution overview datasets with a mesoSPIM21 single-photon light-sheet microscope before transferring the sample into the Schmidt objective for high-resolution imaging. To showcase that the objective can be used in air, we imaged a pollen pellet composed of many individual pollen grains (Fig. 3a). At higher zoom levels, surface features on individual pollen grains become readily apparent. Because the Schmidt objective is a multi-immersion objective, we could then fill the immersion chamber with ECI (n = 1.56) and image the same pollen grains in this high-index medium (Extended Data Fig. 3).

Fig. 3: Example two-photon datasets acquired with the Schmidt objective.
figure 3

Fixed samples were first imaged with a mesoSPIM light-sheet microscope before the sample was transferred to the Schmidt objective. a, Pollen pellet composed of many individual pollen grains imaged in air. b, Functional imaging in a 5-day-old elavl3:GCaMP6s zebrafish larva in vivo (example dataset from one of three imaged larvae). c, BABB-cleared X. tropicalis tadpole stained for Atp1a1 (Alexa Fluor 594, orange) and nuclei (DAPI, grayscale). The large Schmidt FOV allows both imaging of the entire head (≈800 µm across) and imaging of individual developing photoreceptors in the eye (right). The images are examples from one of four imaged tadpoles. d, Thy1-H-labeled coronal mouse brain slice imaged in DBE. At higher magnification, spines on apical dendrites of L5 neurons are visible. The images are examples from one of two imaged mouse brain slices. e, MASH-processed human neocortex stained with acridine orange. The images are examples from one of two imaged samples.

Next, we placed a 5-day-old larval zebrafish expressing the calcium indicator GCaMP6s in neurons in the Schmidt objective and filled it with fish water (n = 1.33). We acquired stacks of the entire zebrafish brain and were able to record neuronal activity in the tectum (Fig. 3b). To illustrate that the objective can be used for imaging cleared samples, we imaged 3-day-old Xenopus tropicalis tadpoles in BABB (n = 1.56), visualizing their developing nervous system and their retinal photoreceptor layer (Fig. 3c and Supplementary Video 2). It was also possible to perform second-harmonic generation (SHG) imaging of muscle fibers in a tadpole embryo tail, resolving individual sarcomeres (Extended Data Fig. 4). We also applied the Schmidt objective to image larger cleared embryos in BABB—for example, a 4-day-old chicken embryo, which is about 6 mm in size (Extended Data Fig. 5 and Supplementary Video 3). Next, we replaced the immersion medium with DBE (also n = 1.56) and inserted a 4-mm-thick coronal slice of an iDISCO-processed4 Thy1-YFP-H mouse brain. In this sample, we were able to visualize spines along apical dendrites (Fig. 3d). We also successfully imaged dopaminergic neurons in a sample from a mouse brain stained for tyrosine hydroxylase (Extended Data Fig. 6). Finally, we acquired a dataset from a MASH-processed22 5 × 7 × 4-mm3 piece of human neocortex in ECI, enabling us to visualize neuronal somata and the dense neuropil (Fig. 3e).

Discussion

Taken together, these examples illustrate how a single Schmidt objective, owing to its large index range, covers a range of applications that would usually require several objectives. Despite having only three optical surfaces, our design outperforms all existing commercial multi-photon microscope objectives for cleared tissue within the parameter space of WD, index range, maximum NA and FOV (Extended Data Fig. 7). Whereas our mirror-based design provides multi-immersion capability basically for free, the reflective ray path means that the objective surrounds the sample, which is similar to light-sheet microscopes for which custom sample holders and mounting techniques are often necessary. In addition, the bigger the sample is, the more it obstructs the excitation path, which can lead to diffraction artifacts. In our prototype, we used samples up to 5 mm in diameter without a severe loss in image quality (Extended Data Fig. 5). Scaling up the entire objective will allow bigger samples, such as entire mouse brains, to be accommodated. It is also possible to design unobstructed off-axis Schmidt objectives that would allow samples of arbitrary lateral size to be imaged. Similarly to a Schmidt telescope, we allow the focal surface to be curved, which did not turn out to be an issue when imaging three-dimensional samples because the z-shift across the FOV is small (that is, Δz = 1.2 µm across a 400-µm FOV). The long path length inside the immersion medium means that the image quality depends on the homogeneity of the liquid. As a consequence, we could not achieve satisfactory image quality in CLARITY samples because the required refractive index matching solutions were not homogeneous enough, whereas imaging in organic solvents was straightforward. This property is not specific to the Schmidt objective, however: any immersion objective with long WD and high NA will show similar behavior. We foresee that the ongoing development of clearing techniques for larger and larger samples will naturally converge toward highly homogeneous imaging media as they provide the best imaging results independent of the microscopy modality. To further improve image quality, it is possible to combine the Schmidt objective with adaptive optics. Owing to their low dispersion and large wavelength range, reflective objectives have previously been used for multi-photon microscopy23,24 but not as fully immersed systems. We think that our work opens an unexplored design space for building immersion microscope objectives. In principle, our concept can be extended to any imaging modality, including wide-field, confocal and light-sheet microscopy. The underlying simplicity of the concept makes it well suited for low-cost objectives that can be mass produced for diagnostic applications. Additionally, in optical design, simplicity begets scalability. Our approach will likely allow the design of ‘mesoscope objectives’ that perform high-resolution (NA > 1) imaging across centimeter-scale FOVs and are capable of extremely high-throughput imaging25,26,27 (Supplementary Table 2). We think that the most promising imaging modality for future multi-immersion Schmidt objectives is light-sheet microscopy. To realize this promise, two challenges must be addressed. First, better chromatic correction across a wide range of immersion media with varying dispersion is necessary because our current design is not achromatic as required for single-photon imaging of fluorophores with broad emission spectra. Second, the field curvature of the Schmidt objective needs to be minimized or the light sheet needs to have a matching curvature. In principle, the latter could be achieved using curved Bessel-like excitation beams28. Addressing both challenges would open new avenues for future multi-immersion light-sheet microscopes to realize the potential of existing imaging sensors with more than 100 megapixels. Beyond that, our development of the Schmidt objective shows that astronomers and microscopists might benefit from closer interactions. In this regard, our work lends credence to a remark that Victor Hugo made in Les Misérables in 1862: ‘Where the telescope ends the microscope begins, and who can say which of the two provides the grander view? Choose’.

Methods

Objective design

The objective was designed using Zemax 2010 and Zemax OpticStudio 18. The aspherical correction plate was manufactured according to custom specifications out of fused silica by Asphericon Jena. The spherical mirror with 30-mm diameter was manufactured out of fused silica (Corning, 7980) and coated with aluminium and a protective layer of SiO2 (Praezisionsoptik Gera). The design process is described in Supplementary Note 1. For imaging in liquid media, the objective was filled with 65 ml of immersion medium.

Setup

Excitation light from a tunable femtosecond Ti:Sapphire laser (Chameleon Ultra II, Coherent) was sent through a Pockels cell (model 350-80 with 302RM controller, Conoptics) and expanded using a ×6 Galilean telescope composed of a −25-mm and a 150-mm achromat (ACN127-25B and AC254-150B-ML, Thorlabs). The beam was then routed to a pair of 10-mm galvo mirrors (6220H, Cambridge Technology) and directed through a 4f system composed of an f = 89 mm scan lens (S4LFT0089/92, Sill Optics) and an f = 300 mm tube lens (88-597, Edmund Optics) to the objective. The galvos could be replaced by a resonant scanner/8-mm galvo pair (CRS4K and 6220H, Cambridge Technology) for fast imaging. Emission light was separated from the excitation beam using a NIR/VIS dichroic (HC 705 LP, AHF) and collected onto two GAsP photomultipliers (H10771P-40 SEL, Hamamatsu) by a ×4.7 demagnifying telescope composed of an f = 90 mm achromat (G322389000, Qioptiq) and a wide-angle eyepiece (Panoptic 19 mm, TeleVue) as previously described29. Custom interchangeable filter cubes allowed the selection of emission channels. In addition, a 720-nm short-pass filter (ET720SP, AHF) located in front of the photomultiplier tube (PMT) blocked unwanted excitation light. PMT signals were amplified and low-pass filtered by a transimpedance amplifier (DHPCA-100 set to 14-MHz bandwidth, 105 V/A gain, Femto). The amplified signal was digitized by an NI-5734 DAQ card connected to an NI-7961R FPGA (both National Instruments). Scanning waveforms were generated using NI-6341 cards in a PXIe-1073 chassis (National Instruments). ScanImage 2017b12 (Vidrio Technologies) running on MATLAB 2019b (MathWorks) was used to control image acquisition. The sample was moved in xyz by an MP130-50-DC-L100 stage with linear encoders (Steinmayer Mechatronik) controlled by a Galil DMC-2132 motor controller. An additional rotation stage (PRM1Z8 with KDC101 controller, Thorlabs) allowed sample rotation. A second MP130 stage allowed xyz translation of the spherical objective mirror. Both mirror and sample were quick-exchangeable using kinematic magnetic mounts (KB25/M, Thorlabs).

PSF measurements

Sample holders for fluorescent beads were built by gluing smaller coverslips (3 mm , CS-3R-0, Warner Instruments) to a 2-mm glass capillary tube (Harvard Apparatus) using silicone adhesive (Würth, Super RTV Silikon). Fluoresbrite YG Microspheres (0.20 µm size, Polysciences) were diluted in distilled water and pipetted on the coverslip. The capillary tube was clamped into a sample holder and inserted into the Schmidt objective. For imaging at an index of n = 1.45, the immersion chamber was filled with a fused silica matching liquid (50350, Cargille). Type A immersion oil (16482, Cargille) was used for measurements at n = 1.51. The liquids were chosen such that the fluorescent beads did not dissolve; other immersion media, such as BABB, DBE and ECI, rapidly dissolved Fluoresbrite beads. For each immersion medium and FOV location, eight beads were measured, and the resulting PSFs were fitted with Gaussian profiles in xyz.

Imaging pollen grains

We glued a pollen granule sold as nutritional supplement (Morga Bluetenpollen, Morga AG) to a 2-mm borosilicate glass tube (TG200-4, Harvard Apparatus) with Super RTV Silicone Transparent (Würth). The dried granules were usually composed of a single type of pollen grain and could be pre-selected for shape and fluorescence under a wide-field microscope. We selected a pollen granule with spikes (echinate sculptures). Immersing pollen granules in water or other polar solvents dissolves them into single pollen, which is why we used ECI to image pollen granules in high refractive index medium in addition to imaging them in air.

Functional imaging of larval zebrafish

We generated larvae by incrossing adult transgenic elavl3:GCaMP6s fish30. Small groups of ≈20 larvae were raised in filtered fish water in 10-cm Petri dishes on a 14-hour light, 10-hour dark cycle at constant 28 °C. For imaging, larvae with strong GCaMP6s fluorescence and no pigmentation (mitfa−/−) were selected. Larvae were embedded in 2% agarose (UltraPure Low Melting Point Agarose, 16520-100, Invitrogen) before imaging. We estimated that 33 mW of laser power was used for imaging (Supplementary Note 1 and Supplemenary Table 1).

This set of animal experiments and procedures was performed in accordance with standard ethical guidelines and was approved by the Cantonal Veterinary Office of the Canton of Zurich.

iDISCO staining and clearing of mouse brains

Mouse experiments and procedures were performed in accordance with standard ethical guidelines and were approved by the Cantonal Veterinary Office of the Canton of Zurich. Mouse brain chunks were stained for neurons and cleared using a modified version of the iDISCO protocol4. C57BL6/J wild-type and Thy1-YFP HJrs/J transgenic (Jackson, 003782) mice aged 4 weeks and 17 weeks, respectively, were anesthetized and perfused, and the brains were post-fixed in 4% paraformaldehyde (PFA) in PBS for 4.5 hours at 4 °C, shaking at 40 r.p.m. Mouse brains were washed in PBS for 3 days at room temperature and 40 r.p.m., with daily solution exchange. Samples were cut into 5-mm3 chunks and dehydrated in serial incubations of 20%, 40%, 60% and 80% methanol (MeOH) in ddH2O, followed by two times 100% MeOH, each for 1 hour at room temperature and 40 r.p.m. Pre-clearing was performed in 33% MeOH in dichloromethane (DCM) overnight at room temperature and 40 r.pm. After two times washing in 100% MeOH, each for 1 hour at room temperature and then 4 °C at 40 r.p.m., bleaching was performed in 5% hydrogen peroxide in MeOH for 20 hours at 4 °C and 40 r.p.m. Samples were rehydrated in serial incubations of 80%, 60%, 40% and 20% MeOH in ddH2O, followed by PBS, each for 1 hour at room temperature and 40 r.p.m. Permeabilization was performed by incubating the samples two times in 0.2% Triton X-100 in PBS, each for 1 hour at room temperature and 40 r.p.m., followed by incubation in 0.2% Triton X-100 + 10% dimethyl sulfoxide (DMSO) + 2.3% glycine + 0.1% sodium azide (NaN3) in PBS for 5 days at 37 °C and 65 r.p.m. Blocking was performed in 0.2% Tween 20 + 0.1% heparine (10 mg ml−1) + 5% DMSO + 6% donkey serum in PBS for 2 days at 37 °C and 65 r.p.m. Samples were stained gradually with polyclonal rabbit-anti-tyrosine hydroxylase antibody (Sigma-Aldrich, AB152) 1:200 or polyclonal chicken-anti-GFP antibody (Aves Labs, GFP-1020) 1:400, followed by secondary donkey-anti-rabbit-Alexa Fluor 594 antibody (Thermo Fisher Scientific, A32754) 1:200 or donkey-anti-chicken Alexa Fluor 594 antibody (Jackson ImmunoResearch, 703-585-155) 1:400 in 0.2% Tween 20 + 0.1% heparine + 5% DMSO + 0.1% NaN3 in PBS (staining buffer) in a total volume of 1.5 ml per sample every week for 2 weeks at 37 °C and 65 r.p.m. Washing steps were performed in staining buffer five times each for 1 hour and then for 2 days at room temperature and 40 r.p.m. Clearing was started by dehydrating the samples in serial MeOH incubations as described above. Delipidation was performed in 33% MeOH in DCM overnight at room temperature and 40 r.p.m., followed by two times 100% DCM each for 15 minutes at room temperature and 40 r.p.m. Refractive index matching was achieved in DBE (n = 1.56) for 4 hours at room temperature.

Staining and clearing of Xenopus embryos

Whole-mount immunofluorescence procedures were adapted from previously described protocols31,32. All experiments were performed in accordance with standard ethical guidelines and were approved by the Cantonal Veterinary Office of the Canton of Zurich. Embryos were fixed at Nieuwkoop/Faber stage 42 for 40 minutes at room temperature in 4% PFA. Embryos were rinsed three times with 1× PBS, dehydrated to 100% MeOH and stored overnight at −20 °C. Bleaching was performed at room temperature shaking under strong light in 10% H2O2/23% H2O/66% MeOH for 48 hours. Embryos were rehydrated to 1× PBS with 0.1% Triton X-100 (PBT), and blocking was performed for 2 hours in 10% CAS-Block/90% PBT (Life Technologies). Staining was performed using the Atp1a1 antibody (1:200, DSHB, A5) diluted in 100% CAS-Block for 48 hours at 4 °C. For nuclear counterstaining, DAPI (20 μg ml−1, Thermo Fisher Scientific, D1306) was added to the primary antibody mixture. Embryos were washed for 3 × 30 minutes with PBT, blocked again for 2 hours (10% CAS-Block/90% PBT) and incubated overnight at 4 °C with secondary antibody (1:250, Alexa Fluor 594, Thermo Fisher Scientific, A32742) diluted in 100% CAS-Block. Embryos were washed for 2 × 1 hour with PBT and then 1 hour in PBS. Embryos were embedded in 2% low-melting agarose and dehydrated as follows: 25% MeOH/75% 1× PBS (2 hours), 50% MeOH/50% 1× PBS (2 hours), 75% MeOH/25% 1× PBS (2 hours) and three times 100% MeOH (2 × 45 minutes, 1× overnight). Clearing was performed in BABB (benzyl alcohol:benzyl benzoate 1:2) overnight.

Neurofilament staining of a whole-mount chicken embryo

The embryo was sacrificed at day 4 of development and incubated in 4% PFA for 2 hours at room temperature. For best staining and clearing results, the embryo was kept in constant, gentle motion throughout the staining procedure. Incubation was at 4 °C. The tissue was permeabilized in 0.5% Triton X-100/PBS for 1 hour, followed by an incubation in 20 mM lysine in 0.1 M sodium phosphat pH 7.3 for 1 hour. In a next step, the embryo was rinsed with five changes of PBS. Non-specific binding was blocked using 10% FCS in PBS for 1 hour. The primary antibody mouse anti-neurofilament (1:2,000, RMO270, Invitrogen, 13-0700) was added for 48 hours. The primary antibody was removed, and the tissue was rinsed with ten changes of PBS and an additional incubation overnight. After re-blocking in FCS/PBS for 1 hour, the embryo was incubated with the secondary antibody goat-anti-mouse IgG-Alexa Fluor 568 (1:1,000, Jackson ImmunoResearch, 115-165-003) for 15 hours. Then, the embryo was washed ten times with PBS, followed by incubation overnight in PBS. For imaging, the tissue was dehydrated in a methanol gradient (25%, 50% and 75% in ddH2O and 2 × 100%, 1 hour each step) and cleared using 1:2 benzyl alcohol:benzyl benzoate (BABB) solution overnight (again, gentle shaking is recommended for dehydration and clearing). The tissue and staining are stable for months when kept at 4 °C in the dark. This set of animal experiments and procedures was performed in accordance with standard ethical guidelines and was approved by the Cantonal Veterinary Office of the Canton of Zurich.

Human brain tissue preparation

The human occipital lobe samples were obtained from the body donation program of the Department of Anatomy and Embryology at Maastricht University. The tissue donor gave their informed and written consent to the donation of their body for teaching and research purposes as regulated by the Dutch law for the use of human remains for scientific research and education (‘Wet op de Lijkbezorging’). Accordingly, a handwritten and signed codicil from the donor posed when still alive and well is kept at the Department of Anatomy and Embryology Faculty of Health, Medicine and Life Sciences, Maastricht University, Maastricht, The Netherlands. The samples were obtained from a female patient (82 years old) diagnosed with Alzheimer’s disease, dementia, aphasia and depression. All methods were carried out in accordance with the relevant guidelines and regulations, and all experimental protocols were approved by the Ethics Review Committee Psychology and Neuroscience. Brains were first fixed in situ by full-body perfusion via the femoral artery. Under a pressure of 0.2 bar, the body was perfused by 10 L of fixation fluid (1.8 vol% formaldehyde, 20% ethanol and 8.4% glycerine in water) within 1.5–2 hours. Thereafter, the body was preserved for at least 4 weeks for post-fixation submersed in the same fluid. Subsequently, brains were recovered by calvarial dissection and stored in 4% PFA in 0.1 M PBS until further processing. The samples were cleared and stained with MASH-AO as previously described22,33, with minor adjustments to the original protocol. The tissue was dehydrated in 20%, 40%, 60%, 80% and 100% MeOH in distilled water for 1 hour each at room temperature, followed by 1 hour in 100% MeOH and overnight bleaching in 5% H2O2 in MeOH at 4 °C. Samples were then rehydrated in 80%, 60%, 40% and 20% MeOH and permeabilized two times for 1 hour in PBS containing 0.2% Triton X-100 (PBST). This was followed by a second bleaching step in freshly filtered 50% aqueous potassium disulfite solution. The samples were then thoroughly rinsed in distilled water five times and washed for another 1 hour. For staining, the samples were incubated in 0.001% acridine orange solution in McIlvain buffer33 (phosphate-citrate buffer) at pH 4 for 5 days at room temperature. After 2.5 days, the samples were flipped to allow for equal penetration of the dye from both sides. After staining, samples were washed two times for 1 hour in the same buffer solution, dehydrated in 20%, 40%, 60%, 80% and 2 × 100% MeOH for 1 hour each and delipidated in 66% DCM/33% MeOH overnight. These steps were followed by 2 × 1-hour washes in 100% DCM and immersion in ECI22,33.

Reporting summary

Further information on research design is available in the Nature Portfolio Reporting Summary linked to this article.